The 10kw air-cooled vehicle OBC charger is a high-power density, high-efficiency charger specifically developed for new energy vehicles such as lithium battery pure electric logistics vehicles, buses, and engineering machinery. It adopts a modular, standardized, and universal design approach. The charger supports three-phase AC input and offers a fully adjustable DC output voltage range.
The product is designed with fully digital control technology, providing flexible and intelligent control, excellent protection characteristics, and strong system robustness. It comes equipped with a built-in microprocessor that communicates with the monitoring unit. Internal parameters can be set or adjusted via the CAN interface by the superior monitoring unit.
It features multiple protection functions such as input over-voltage/under-voltage protection, output over-current protection, output over-voltage protection, output short-circuit protection, and over-temperature protection.
|
Model |
Input Voltage |
Output Power |
Output Voltage |
Output Voltage Range |
Output Current Range |
|
TBD |
380VAC |
10KW |
24VDC |
0-40VDC |
0-300A |
|
TBD |
380VAC |
10KW |
48VDC |
0-68VDC |
0-180A |
|
TBD |
380VAC |
10KW |
72VDC |
0-95VDC |
0-135A |
|
TBD |
380VAC |
10KW |
108VDC |
0-135VDC |
0-90A |
|
TBD |
380VAC |
10KW |
144VDC |
0-180VDC |
0-66A |
|
TBD |
380VAC |
10KW |
360VDC |
0-500VDC |
0-27A |
|
TBD |
380VAC |
10KW |
540VDC |
0-720VDC |
0-18A |
| Model | |
|---|---|
| Vehicle-mounted Power Supply Type | Air-cooled On-board Charger Assembly |
| Power Model | 24V 48V 72V 108V 144V 360V 540V |
| Input Characteristics | |
| Rated Input Voltage | 380VAC |
| Rated Input Voltage Frequency | 50Hz |
| Input Frequency Range | 45¡«65Hz |
| Inrush Current at Start-up | ≤45A |
| Input Power Factor | ≥0.99£¨@380Vin, Pomax£© |
| Output Characteristics | |
| Rated Output Power | 10KW |
| Output Voltage Range V | 0-40 0-68 0-95 0-135 0-180 0-500 0-720 |
| Output Current Range A | 0-300 0-180 0-135 0-90 0-66 0-27 0-18 |
| Voltage Regulation Accuracy | ±1% |
| Current Regulation Accuracy | ±0.5A£¨Io≤10A£©& ≤±5%£¨Io>10A£© |
| Voltage Ripple Factor | ≤1% |
| Output Response Time | ≤200mS |
| Typical Efficiency | ≥91% ≥92% ≥93% ≥93% ≥94% ≥94% ≥94% |
| Protection Characteristics | |
| Over/Under Voltage Protection | Input over/under voltage shutdown and self-recovery, output over/under voltage shutdown and self-recovery. |
| Output Reverse Connection and Short Circuit Protection | Output short circuit or reverse connection causes shutdown and self-recovery. |
| Over-temperature Protection | When the heat sink temperature is higher than 75¡æ, reduce the output power; when the temperature is higher than 95¡æ, disconnect the circuit. The charger resumes output when the charging temperature drops below 85¡æ. |
| Environmental Conditions | |
| Operating Ambient Temperature | -40¡æ¡«+65¡æ (Automatic derating operation when ambient temperature is high) |
| Storage Temperature | -40¡«95¡æ |
| Humidity | 5%¡«95% |
| IP Rating | IP67 |
| Cooling Function | Forced Air Cooling |
| Communication Function | CAN Bus Control |
| Charging Function | Can charge normally when receiving charging commands; the charger is in standby mode without commands. |

The input/output end of the power supply should be supplemented with a blown fuse or other overcurrent protection device;
The possible electrical hazards at the output end of the product must be considered to ensure that the end product user will not come into contact with the product; The manufacturer of the terminal equipment must design the appropriate protection scheme to ensure that the operation will not cause danger due to accidental contact of the engineer or tool with the source terminal;
Once the safety protection of the equipment is damaged, the equipment must stop working and refer to the relevant maintenance regulations.
When the power supply device is switched from a cold environment to a warm environment, condensation may cause leakage hazards, so the grounding requirements must be strictly implemented.
Only a qualified person can connect the equipment to the power supply.
The power supply must be shut down for five minutes, so that the capacitor has sufficient discharge time before the power supply equipment can be maintained.
Pay attention to the use of safety: there are safety warning signs, high pressure signs, avoid hand contact, so as to avoid electric shock, burns.