This battery system is suitable for household energy storage and small and medium-sized commercial storage. It uses 3.2 V 100Ah lithium lifepo4 battery cells from a 2-in-8 battery module and an intelligent BMS to form a 25.6V 200Ah lithium battery system. The system supports up to 6 groups of batteries in parallel. The system is prohibited from being used in series and mixed with other batteries of different brands and models.
Function Introduction
- Cell Voltage Monitoring: Measures the voltage of up to 16 battery cells with an accuracy of ±20 mV.
- Temperature Monitoring: Equipped with two battery temperature sensors, one ambient temperature sensor, and one MOS temperature sensor; accuracy of ±2 °C.
- Battery Capacity and Cycle Count: Supports actual capacity calibration through a full charge/discharge cycle. Remaining capacity estimation accuracy is within 5 %. Configurable charge/discharge cycle times and full cycle durations.
- Intelligent Cell Balancing: Flexible charging and static balancing strategies can be set to extend battery service life.
- Communication Interface: Enables remote monitoring and control via PC or intelligent front‑end using telemetry, remote signaling, remote adjustment, and remote control commands. Complies with the YD/T 1363.3 protocol and supports cascade communication.
- Historical Data Logging: Automatically records and saves real‑time battery status and alarm information upon abnormality. Stores up to 500 historical fault records.
- Parameter Configuration: Allows comprehensive BMS parameter settings through the monitoring system, including cell overvoltage/undervoltage thresholds, total battery overvoltage/undervoltage, charge/discharge overcurrent limits, battery high/low temperature thresholds, battery capacity, operating modes, and charge/discharge current limits.
- Operating Modes: Configurable modes include charge/discharge current limiting, constant voltage output, and direct output.
- Protection Functions: Provides multiple protections such as hardware protection, battery protection, high/low temperature protection, and output short circuit protection.
Specifications
| Item |
Specification |
| Battery Configuration |
2P8S |
| Rated voltage |
25.6V |
| Operating voltage range |
21V~ 29.2V |
| Rated capacity |
200Ah |
| Rated |
5.12KWh |
| Standard charge/discharge current |
100A @ 25 ±2¡æ |
| Maximum charging current |
100A @ 25 ± 2¡æ |
| Maximum discharge current |
100A @ 25 ±2¡æ |
| Operating temperature |
0~ 40 ¡æ(Charge) |
| -20~ 40 ¡æ(Discharge) |
| Storage temperature and humidity |
-10 ¡æ ~35 ¡æ (stored within one month) |
| 25 ± 2 ¡æ (storage within three months) |
| Dimensions (L x W x H) |
( 600) ×( 368 ) ×( 150 ) mm |
| weight |
46Kg ±3kg |
| Cycle life |
6000 cycles @25¡æ 50A charge and discharge current, 70% standard capacity 80 % DOD |
| IP Rating |
IP 20 |
| Communication |
CAN&RS485 |
| Altitude |
0- 3 000 m |
| Humidity range |
5~ 80 % |
Product Details
Dimensions and interface diagram

Electrical Schematic Diagram