RA6P6 series on-board charger is a high-power density, high-efficiency unit specifically designed for new energy vehicles, including pure electric and logistics vehicles utilizing lithium-ion batteries. The module accepts a wide AC input range of 90–265 VAC and provides a fully adjustable DC output voltage.
Utilizing full digital control technology, the charger features flexible and intelligent operation, excellent protective characteristics, and strong system robustness. An embedded microprocessor enables communication with an upper-level monitoring system via a CAN interface, allowing for remote parameter configuration and adjustment.
It incorporates multiple protection functions, including:
Input over-voltage and under-voltage protection
Output over-current and over-voltage protection
Output short-circuit protection
Over-temperature protection
|
Model |
Input voltage range |
Rated output power |
Rated output voltage |
Output voltage/current range |
|
RA6P6700 |
90~265VAC |
6.6KW |
700VDC |
0~850V/0~9A |
|
RA6P6540 |
90~265VAC |
6.6KW |
540VDC |
0~720V/0~12A |
|
RA6P6360 |
90~265VAC |
6.6KW |
360VDC |
0~500V/0~18A |
|
RA6P6144 |
90~265VAC |
6.6KW |
144VDC |
0~190V/0~44A |
|
RA6P6108 |
90~265VAC |
6.6KW |
108VDC |
0~140V/0~60A |
|
RA6P6080 |
90~265VAC |
6.6KW |
80VDC |
0~105V/0~80A |
| Items | RA6P6700 | RA6P6540 | RA6P6360 | RA6P6144 | RA6P6108 | RA6P6080 |
|---|---|---|---|---|---|---|
| On-board power supply type | Air-cooled on-board charger | Air-cooled on-board charger | Air-cooled on-board charger | Air-cooled on-board charger | Air-cooled on-board charger | Air-cooled on-board charger |
| Rated input voltage | 220VAC | 220VAC | 220VAC | 220VAC | 220VAC | 220VAC |
| Input voltage range | 90~265VAC | 90~265VAC | 90~265VAC | 90~265VAC | 90~265VAC | 90~265VAC |
| Input voltage frequency | 50Hz | 50Hz | 50Hz | 50Hz | 50Hz | 50Hz |
| Enter the frequency range | 45~65Hz | 45~65Hz | 45~65Hz | 45~65Hz | 45~65Hz | 45~65Hz |
| Start the inrush current | ≤32A | ≤32A | ≤32A | ≤32A | ≤32A | ≤32A |
| Power factor | ≥0.99£¨@220Vin,Pomax£© | ≥0.99£¨@220Vin,Pomax£© | ≥0.99£¨@220Vin,Pomax£© | ≥0.99£¨@220Vin,Pomax£© | ≥0.99£¨@220Vin,Pomax£© | ≥0.99£¨@220Vin,Pomax£© |
| Rated output power | 6.6KW | 6.6KW | 6.6KW | 6.6KW | 6.6KW | 6.6KW |
| Rated output voltage | 700VDC | 540VDC | 360VDC | 144VDC | 108VDC | 80VDC |
| Output voltage range | 720 | 540 | 360 | 144 | 108 | 80 |
| Output current range | 0~850V/0~9A | 0~720V/0~12A | 0~500V/0~18A | 0~190V/0~44A | 0~140V/0~60A | 0~105V/0~80A |
| Typical efficiency | ≥94% | ≥94% | ≥94% | ≥92% | ≥92% | ≥92% |
| Voltage ripple stabilization | ≤1% | ≤1% | ≤1% | ≤1% | ≤1% | ≤1% |
| Voltage/frequency coefficient | ≤1% | ≤1% | ≤1% | ≤1% | ≤1% | ≤1% |
| Output response time | ≤200ms | ≤200ms | ≤200ms | ≤200ms | ≤200ms | ≤200ms |
| Operating noise | ≤60dB | ≤60dB | ≤60dB | ≤60dB | ≤60dB | ≤60dB |


The input/output end of the power supply should be supplemented with a blown fuse or other overcurrent protection device;
The possible electrical hazards at the output end of the product must be considered to ensure that the end product user will not come into contact with the product; The manufacturer of the terminal equipment must design the appropriate protection scheme to ensure that the operation will not cause danger due to accidental contact of the engineer or tool with the source terminal;
Once the safety protection of the equipment is damaged, the equipment must stop working and refer to the relevant maintenance regulations.
When the power supply device is switched from a cold environment to a warm environment, condensation may cause leakage hazards, so the grounding requirements must be strictly implemented.
Only a qualified person can connect the equipment to the power supply.
The power supply must be shut down for five minutes, so that the capacitor has sufficient discharge time before the power supply equipment can be maintained.
Pay attention to the use of safety: there are safety warning signs, high pressure signs, avoid hand contact, so as to avoid electric shock, burns